MRR111 Moisture Resistant Repair
DESCRIPTION
PrepWorx MRR111 is a moisture-tolerant, fast-setting, low-slump patching and repair compound designed for use at any depth. This high-strength, Portland cement-based formula dries quickly, sand easily, making it ideal for preparing surfaces for most floor coverings, including wood products. Engineered to withstand heavy wear, it is perfect for filling holes, repairing cracks, and making general surface repairs on concrete substrates. It is also recommended for smoothing and repairing concrete stairs and creating ramp transitions.
APPROVED SUBSTRATES
-
Produces flat, smooth surfaces for installing textile, resilient, ceramic, and engineered wood floor coverings
-
Well-bonded hard surface flooring (e.g., terrazzo, ceramic tile, stone, epoxy coatings)
-
For use over radiant heat systems
-
All substrates must be primed prior to installation.
-
Do not use over chemically abated substrates.
|

|
SUBSTRATE TESTING
-
No moisture testing requirements.
-
Refer to substrate moisture limits per flooring installation requirements.
-
Ensure that concrete is dry before application, provided the site is absent of hydrostatic pressure.
-
If RH exceeds acceptable levels, apply a moisture control system like PrepWorx MCS310 or PrepWorx VBS311.
-
This product may be installed over concrete with relative humidity (RH) levels up to 100%, with absent of hydrostatic pressure.
SUBSTRATE PREPARATION
-
Substrates must be structurally sound, clean, and surface dry.
-
Substrate must be free of dust, dirt, oil, grease, paint, curing agents, concrete sealers, loosely bonded toppings, loose particles and any other substance or condition that may prevent or reduce adhesion.
-
Any weakly bonded or soft surface material, such as loose patching compounds, leveling compounds, floor coverings, or coatings, must be removed.
-
Do not use sweeping compounds.
-
Do not apply this product (over) chemically abated adhesive surfaces.
-
All substrates must be primed with PrepWorx VBC301 prior to application.
Concrete Substrate:
-
Clean surfaces using mechanical methods and avoid using acid etching or sanding, which will not provide adequate bonding preparation.
- For dormant cracks wider than 1/32” (0.8 mm), PrepWorx CJR400 may be used to repair.
-
It is recommended to fill dormant cracks and saw cuts deeper that 1”, using PrepWorx MRR111.
-
Ensure all moving joints, including expansion and isolation joints, as well as moving cracks, are properly addressed and accounted for throughout the entire flooring system, including the finish layer. No flooring material should be installed over these areas.
Wood Substrate:
-
Wood substrates must provide a rigid base and be securely fastened without excessive vertical movement. The surface of the wood must be clean and free of oils, grease, wax, dirt, varnish, shellac, and any contaminates that would impair adhesion. If necessary, sand down to bare wood. Do not apply totalworx products directly to fire-retardant or pressure-treated wood surfaces.
-
Prime wood surface with PrepWorx VBC301.
WARNING: DO NOT SAND, DRY SWEEP, DRY SCRAPE, DRILL, SAW, BEAD BLAST OR MECHANICALLY CHIP OR PULVERISE EXISTING RESILIENT FLOORING, BACKING, LINING FELT, ASPHALTIC “CUTBACK” ADHESIVES OR OTHER ADHESIVES. These products may contain either asbestos fibers and/or crystalline silica. Avoid creating dust. Inhalation of such dust is a cancer and respiratory tract hazard. Smoking by individuals exposed to asbestos fibers greatly increases the risk of serious bodily harm. Unless positively certain that the product is a non‐ asbestos‐containing material, you must presume it contains asbestos. Regulations may require that the material be tested to determine asbestos content and may govern the removal and disposal of material. See current edition of the Resilient Floor Covering Institute (RFCI) publication Recommended Work Practices for Removal of Resilient Floor Coverings for detailed information and instructions on removing all resilient covering structures. For current information go to www.rfci.com.
APPLICATION INSTRUCTIONS AND COVERAGE RATES
Read and follow the product specific installation guidelines for layout, design and any special instructions for installation.
PrepWorx MRR111 requires the floor surface to be primed with PrepWorx VBC301 primer before application.
-
Installation site must be acclimated with HVAC in operation, or the temperature must be controlled between 60-77 °F (16-25 °C) and the ambient relative humidity controlled below 65% before, during and for 72 hours after the installation.
Mixing
Application
Coverage Rates
Coverage Rate per 20lbs. Bag (approx.*)
*Actual coverage may vary depending on substrate conditions
PRODUCT CHARACTERISTICS
|
Weight
|
20lbs / bag
|
| Pallet Quantity |
72 |
| Pallet Weight |
1500 |
| Physical State |
Dry Powder |
| Color |
Gray |
| Shelf Life |
1 Year in original unopened packaging, when stored indoors in dry, moderate conditions between temperatures of 50F - 90F (10C - 32C) |
| Storage |
Store away from direct sunlight in a well-ventilated, cool, dry area. If storing after opening, remove all air from packaging and seal tightly. |
| Freeze/Thaw |
Freeze thaw stable |
|
Compression Strength
|
Compressive: 4,300 psi at 28 days (ASTM C109)
Flexural: 1,000 psi @ 28 days (ASTM C348)
|
|
Cleaning Instructions
|
While still fresh, wash hands, tools and equipment with warm soapy water.
|
|
Traffic
|
45 minutes (depths < 3/8”)
|
| Ready for Covering |
1 hour. depths < 3/8" (9 mm)* // 1-3 hours depths between 3/8"-3/4" (9 mm-18 mm)* // 18 hours for wood flooring* |
* At 70 °F (21 °C) and 65% ambient relative humidity. Surface profile and porosity, application depth, temperature, and humidity will affect dry time and coverage
Environmental
- California South Coast Air Quality Management District Rule 1168
- California Department of Public Health Section 01350
- SCS Global Advantage Gold - SCS-IAQ-11081
LEED IEQ Credit Information (2009 and V4)
| Credit Requirement |
Status |
Comment |
| Meets General Emissions Evaluation Criteria |
Complies |
SCS-IAQ-11081 |
| VOC’s (Rule #1168 of California SCAQMD amended October 6, 2017) |
Complies |
VOC Content Between 0.5 mg.m3 and 5.0 mg/m3 |
WARRANTY
Standard product warranty is 1 year. When combined with certain PrepWorx moisture management and flooring adhesive products the term of warranty is extended ranging from 10 to 20 years. See Shaw System Warranty (Warranties) for complete details. PrepWorx Floor Preparation 1 Year Limited Warranty
PRECAUTIONS
Carefully read and follow all precautions and warnings on the product label. For complete safety information, please refer to the Safety Data Sheet.